SludgeWatch 715 Sludge Blanket Detector

SludgeWatch 715 Sludge Blanket Detector The SludgeWatch 715 provides a simple, low cost method of spot checking the sludge blanket level in a wide variety of settlement tanks. The cable reel design removes the need for any additional carrying bag. ... Sewage Treatment Thickeners: Note: Sensor ranges and detection points are approximate and ...

WhatsApp: +86 18221755073
How to Operate a Thickener

 — If it is a tailings thickener, you are wasting water, which is unforgiveable in the desert. If it is a concentrate thickener, you . may be handing the filter operator a headache, which he may return with interest. If it is a C.C.D. thickener, you are only making trouble for yourself farther along the line.

WhatsApp: +86 18221755073
High Rate Thickener Bed Level Detector Manufacturer

Outotec Thickening technologies Bed Level Outotec High Rate Thickener control Control solution The disturbances can be controlled by means of a feedforward algorithm equipped with adaptive tuning functionality to allow optimal feedforward gain to be set This results in stable solids inventory (ie bed mass) control down the circuit, and therefore …

WhatsApp: +86 18221755073
Thickeners

 — Factors determining efficiency of Thickener. Several types of thickeners have been developed and classified according to the arrangement of feed and discharge in the various compartments. For effective thickener control, key considerations are bed mass inventory, underflow density and flow, bed level, overflow clarity and flocculent dosing.

WhatsApp: +86 18221755073
Sludge Finder 2 | Sludge Blanket Level Control | Pulsar

Sludge blanket level control from the Pulsar Sludge Finder 2 provides maintenance-free, reliable, continuous, sludge blanket level measurement for primary, ... and finally ensures that further sludge handling processes such as thickeners and dewatering equipment are all performing to their maximum with the correct concentration of sludge. ...

WhatsApp: +86 18221755073
Thickeners

Diefenbach thickeners are comprised of a tank, feed pipe feedwell, rake (and pickets, depending on the thickener style), a bridge containing the rake drive mechanism, and a chemical dosing system. ... Diefenbach thickeners come with density monitoring systems that allow for optimal control of bed level, underflow density and automation of ...

WhatsApp: +86 18221755073
Lamella Thickeners | Hawk Measurement Systems

Lamella thickeners are high rate thickeners that use a series of angled impact plates to increase settling rates. The problems for the clients thickener were: When the bed level came up to high and entered the plate region the efficiency of the thickener dropped. The bed would sometimes break up and flow over into the launders.

WhatsApp: +86 18221755073
Control Strategies for Minerals Thickening (Part 2)

 — Here, a SmartDiver was installed (figure 1) to get the thickener level measurements. Then expert control was implemented for underflow density and flocculant control. Fig 1: SmartDiver® installed on a Thickener Plant. The under-flow density control uses measurements of heavy mud level, rake torque, bed pressure, underflow density, …

WhatsApp: +86 18221755073
Five Reasons for Measuring Density in Thickening Processes

 — Examples of installation points are the feed, underflow, overflow and inside the thickener tank. Flow meters are combined with density meters to calculate the mass flow in the underflow and feed of the thickener. Inside the tank, submerged ultrasonic probes are used for tank profiling, interface detection and measuring the bed level.

WhatsApp: +86 18221755073
Selecting Thickener Depth Determination

 — Then, considering the low feed rate situation, the expected bed drop would be: and the maximum interface level would be 0.5 + 0. 42 – 0.14 = 1.06 m. This bed depth should be added to the feedwell depth to give the approximate minimum sidewall depth required for the thickener. Thickener Compression Tests

WhatsApp: +86 18221755073
Complete bundle for bed level measurement | Endress+Hauser

The ultrasonic Turbimax CUS71D bed level sensor with wiper is perfectly suited for continuous interface measurement in thickeners. It provides real-time values for quick control of valves and actuators and ensures safe, economic and efficient sedimentation processes in combination with the Liquiline CM442 single channel transmitter and the ...

WhatsApp: +86 18221755073
Tailings Thickeners Level Sensor

Rake Torque from the scraper also works on total load and is affected by density and therefore cannot be used to control bed level. The displacement float sticks and suffers from build-up. The Sonar Acoustic transmitter can be calibrated to work with two different densities. We can track the Compact Bed Level to control the underflow pump.

WhatsApp: +86 18221755073
Thickeners

Thickeners — or Clarifiers, depending on the application — can be used to recover immediately reusable process water, as well as extract fines and other materials. Thickeners are used by mineral and aggregate …

WhatsApp: +86 18221755073
Thickener & Clarifier Level Control Solutions

The ORCA Sonar series will measure up to two density interfaces simultaneously, either bed level (RAS blanket) and floc/fluff layer (clarity of water), using the ORCA Sonar hardware. HAWK manufacturers the largest range of sonar transducers to provide optimized performance, for all bed level thickener applications.

WhatsApp: +86 18221755073
Control Strategies for thickeners

 — There are different targets to optimize thickener performance: To ensure optimum solids content in the tailings impoundment, an underflow density target is used. Additionally, this target ensures optimum water reclaim for the mill. A bed/mud level target is used to obtain optimum loading in the thickener without overloading the drive mechanism.

WhatsApp: +86 18221755073
Thickeners

Thickeners — or Clarifiers, depending on the application — can be used to recover immediately reusable process water, as well as extract fines and other materials. Thickeners are used by mineral and aggregate producers, as well as by environmental contractors in industries such as wastewater…

WhatsApp: +86 18221755073
Sonar Level Interface Technology

It can measure either bed level (RAS blanket) or floc/fluff layer (water clarity). The transducer design includes three to seven sonar crystals mounted in a single head. Each sonar array produces a concentrated sonar beam, providing more emitted power and collecting more returned signals for optimal performance.

WhatsApp: +86 18221755073
Sludge Blanket Monitoring | Sludge blanket detection

Using a sensitive, infrared sensor, a high-level sludge blanket alarm will alert site operators to a problem before it hits the discharge point. Eliminate Health Hazard Triggering the de-sludging process when required rather than relying on a timer eliminates unnecessary pumping costs and produces a better quality sludge for de-watering.

WhatsApp: +86 18221755073
OUR NEWSLETTER

join our newsletter

Subscribe to the Puik Store mailing list to receive updates on new arrivals, special offers
and other discount information.