Solved Q-3 Particles of the average feed size of 50 x 104m
At this rate, the crusher consumes 40 kW of power of which 5 kW are required for running the mill empty. Calculate the power consumption if 12 tonnes/h of this product is further crushed to 5 x104m size in the same mill? ... Assume that Rittinger's law is applicable. Q-4 Find the power required for crushing 5 tonne/h of limestone (Rittinger's ...